EPlacement F3 Female

Icona
Icona
Icona

Results Female

Distance from Cz to C3: --

Distance from Ns to F3: --

The error with Beam F3 method would be approximately: --

Imatge Equacions Neurally F3

EPlacement F3 Male

Icona
Icona
Icona

Results Male

Distance from Cz to C3: --

Distance from Ns to F3: --

The error with Beam F3 method would be approximately: --

Imatge Equacions Neurally F3

FEMALE: Beam Method

Euclidian distance between the SI 10/20 point F3 and the ones located with BeamF3 and BeamF3 Adjusted methods (sample of 250 realistic heads):
Dist BeamF3 (mm) Dist BeamF3 Aj. (mm)
Mean ± SD 5.49 ± 0.93 7.57 ± 1.43
Minimum 3.62 4.89
Maximum 7.29 9.87

FEMALE: EPlacement Device

Euclidian distance between the SI 10/20 point F3 and the one located with Neurally F3 method (sample of 250 realistic heads):
Dist EPlacement F3 (mm)
Mean ± SD 0.29 ± 0.1
Minimum 0.022
Maximum 0.612
Imatge Punt F3

MALE: Beam Method

Euclidian distance between the SI 10/20 point F3 and the ones located with BeamF3 and BeamF3 Adjusted methods (sample of 250 realistic heads):
Dist BeamF3 (mm) Dist BeamF3 Aj. (mm)
Mean ± SD 5.86 ± 1.05 8.22 ± 1.48
Minimum 3.56 4.95
Maximum 7.92 10.65

MALE: EPlacement Device

Euclidian distance between the SI 10/20 point F3 and the one located with Neurally F3 method (sample of 250 realistic heads):
Dist EPlacement F3 (mm)
Mean ± SD 0.29 ± 0.1
Minimum 0.02
Maximum 0.82